VOCSN PRO: 5 Therapies One Mode Portable Ventilator

  • Portable Ventilator

  • Built in 02 Concentrator

  • Built in Cough Assist

  • Built in Suction

  • Built in Nebulizer

Price: $21,000 Per Unit. Contact Us for pricing on other products.


Portable ventilator only weights 18 lbs!!

Portable Ventilator: Ventilation can deliver all ventilation parameters as listed on the ventilation tech spec.

Oxygen: Can deliver Fi02 from external high pressure source, low pressure 02, and oxygen from internal concentrator. Can pulse dose from external high pressure source.

Cough Assist: Cough can deliver all cough parameters we currently have.

Suction: Suction can utilize all suction features.

Nebulizer: Can nebulize from internal compressor and compensate for external nebulization.


VOCSN System Tech Specs

For more information call: 1-424-247-8183

Patients

  • Invasive and non-invasive ventilation (including mouthpiece)
  • Adult and pediatric patients greater than 5 kg

Hospitals

  • Emergency departments
  • Step-down units
  • Military hospitals

Institutions

  • Long term acute care (LTAC)
  • Skilled nursing facilities
  • Long-term care/nursing homes

Transport

  • Inter-hospital
  • Intra-hospital
  • Emergency medical services
  • Military transport

Alarm Volume

  • 65 to 85 decibels

Battery Power

  • Up to 9 hours of continuous use (ventilation only)
  • 2 external hot swappable lithium-ion batteries (5,800 mAh each)
  • 1 Internal battery (3,900 mAh)
  • Note: Simultaneous use of therapies will decrease battery operating time

Clinician Lock to Restrict User Access to Settings

  • On/Off
  • 2 external hot swappable lithium-ion batteries (5,800 mAh each)
  • Permissions feature can be enabled to allow certain settings to be adjusted

Enable and Disable Therapies

  • Enable/Disable any of the five therapies based on patient needs

Power Sources

  • AC (wall plug-in)
  • DC (wheelchair and external batteries)
  • VOCSN Batteries (3 batteries: 15,500 mAh total)

External Power Requirements

  • AC Power:
    • Sine AC mains waveform
    • Rated Voltage: 100 to 240 VAC, 50 to 60 Hz
    • Power for V+O+C+S+N(+Pro): ≤288 VA average, 420 peak
    • Power for V+C(+Pro): ≤180 VA average, 240 VA peak
  • DC Power:
    • 20.0 to 30.3 VDC, as measured at the connection to the device, through 0 to 350 W instantaneous loads
    • Power for V+O+C+S+N(+Pro): ≤200 W average, 350 W peak
    • Power for V+C(+Pro): ≤150 W average, 200 W peak
    • Intended for connection to 24 V (27.2 VDC typical) batteries
    • Female XLR3 connection port with the following pin configuration: Pin 1 Signal: V+, Pin 2 Signal: RTN, Pin 3 Signal: N/A (Unused)

Clinician Lock to Restrict User Access to Settings

  • On/Off
  • 2 external hot swappable lithium-ion batteries (5,800 mAh each)
  • Permissions feature can be enabled to allow certain settings to be adjusted

Dimensions

  • Width: 10.25 inch (26 cm)
  • Height: 11 inch (28 cm)
  • Depth: 7.5 inch (19 cm)

User Interface

  • 7 inch (17.75 cm) easy to use color LCD touchscreen

Weight (w/batteries)

  • V+O+C+S+N+Pro: 18.3 lbs (8.3 kg)
  • V+O+C+S+N: 18.1 lbs (8.3 kg)
  • V+C+Pro: 14 lbs (6.4 kg)
  • V+C: 12.5 lbs (5.7 kg)

Operating Environment

  • Temperature: 5 °C to 40 °C
  • Humidity: 15% to 90% (non-condensing)
  • Atmospheric: 700 to 1060 hPa

Electromagnetic Compatibility and Protection

  • IEC 60601-1-2
  • Additional ESD levels: ±8 kV contact / ±15 kV air
  • Additional Radiated RF Immunity level: 20 V/m
  • Additional Magnetic Fields level: 30 A/m
  • Tested for RFID immunity

Ventilation Tech Specs

For more information call: 1-424-247-8183

9 Modes of Ventilation

  • Spontaneous
  • Bi-Level (with functionality similar to S/T, Timed, and BiPAP ventilation)
  • Assist/Control-Pressure
  • Assist/Control-Volume
  • SIMV-Pressure (including CPAP)
  • SIMV-Volume
  • Vol. Targeted-PS (with functionality similar to AVAPS® and PVRS)
  • Vol. Targeted-PC (with functionality simliar to PVRC)
  • Vol. Targeted-SIMV (with functionality similar to SIMV+PVRC)

Apnea Rate

  • 4 to 60 BPM

Breath Rate

  • 0 to 60 BPM

Circuit Compensation

  • Automatic circuit compensation

Customizable Ventilation Therapy Presets

  • 3 presets, each with customizable names and settings

EPAP/PEEP

  • Active circuit: 0 to 25 cmH2O
  • Passive circuit: 4 to 25 cmH2O

FiO2

  • 21 to 100%

Flow Cycle

  • 10 to 90%

Flow Trigger

  • Active or Passive Circuit: 0.5 to 9.0 L/min
  • Mouthpiece circuit: 0.5 to 3.0 L/min (breaths triggered by patient effort or by placing your mouth on the mouthpiece)

Inspiratory Positive Airway Pressure (IPAP)

  • 4 to 40 cmH2O above ambient

Inspiratory Time

  • 0.3 to 5.0 seconds

Leak Compensation

  • On/Off
  • Automatic Leak+ compensation up to 175 L/min at 20 cmH2O

Pressure Control

  • 1 to 50 cmH2O above PEEP (PEEP compensated)

Pressure Control

  • 1 to 50 cmH2O above PEEP (PEEP compensated)

Pressure Control Flow Termination

  • On/Off

Pressure Support

  • 0 to 40 cmH2O above PEEP (PEEP compensated)

Rise Time

  • 1 (100 ms) to 6 (600 ms) to target 67% of set pressure

Sigh

  • On/Off
  • 150% of the prescribed volume is delivered once every 100 breaths

Tidal Volume

  • 50 to 1500 mL

Time Cycle

  • 0.3 to 3.0 seconds

Airway Pressure Manometer

  • 0 to 80 cmH2O

Breath Rate

  • 0 to 100 BPM

Calculated FiO2

  • 21 to 100%
  • The calculated FiO2 monitor calculates the delivered FiO2 during pulse dose oxygen

Exhaled Tidal Volume

  • 0 to 2000 mL

FiO2 Monitor

  • 15 to 95%, >95%

Graphic Waveforms

  • Pressure (-16 to 80 cmH2O)
  • Flow (±120 L/min)
  • Volume (0 to 2000 mL)

I:E Ratio

  • 9.9:1 to 1:9.9

Leak

  • 0 to 200 L/min

Mean Airway Pressure

  • 0 to 50 cmH2O

Minute Volume

  • 0 to 60 L

Positive End Expiratory Pressure (PEEP)

  • 0 to 45 cmH2O

Peak Inspiratory Pressure (PIP)

  • 0 to 85 cmH2O

Apnea

  • Off, 10 to 120 seconds

Battery Alarms

  • Battery Use Alarm
  • Internal Battery Low
  • Internal Battery Critically Low

Circuit Integrity Alarms

  • Check Patient Circuit
  • Patient Circuit Disconnect

Device Alarms

  • Device Maintenance
  • Inoperative Alarm
  • System Fault

High Breath Rate

  • Off, 10 to 99 BPM

High FiO2

  • Off, 24 to 99%

High Minute Volume

  • Off, 1 to 59 L

High PEEP

  • Off, 3 to 20 cmH2O above set PEEP

High Pressure

  • 10 to 80 cmH2O

High Pressure Alarm Delay

  • None, 1 to 2 breaths

Low Breath Rate

  • Off, 4 to 80 BPM

Low Inspiratory Pressure

  • Off, 1 to 40 cmH2O

Low Minute Volume

  • Off, 0.1 to 50 L

Low PEEP

  • Off/On
  • When on, automatically activates when monitored PEEP falls 5 cmH2O below the set PEEP

Very Low FiO2

  • FiO2 less than 18%

Multi-View

  • Logs, graphs, and trends Ventilation monitors (such as Vte), alarm activations, configuration changes, and more

For more information call: 1-424-247-8183